Radon Information Before & After Photos
Click on a photo to enlarge.
Radon Mitigation - Danbury, IA
7 pCi/L Radon Levels Addressed with Professional Mitigation System
A home recently tested at 7 pCi/L, prompting the homeowner to move forward with professional radon mitigation. With elevated radon levels detected, the goal was to create a reliable system that would reduce radon exposure and improve indoor air quality. The mitigation plan included routing the system from the sump area through the office for an interior installation. An exterior option was also considered to accommodate the home's layout while maintaining an effective path for safely venting radon outdoors.
Radon Mitigation - Holstein, IA
Radon Levels in Duplex Require a Customized Mitigation System
Testing revealed radon levels of 22 pCi/L in this duplex, well above the EPA's recommended action level of 4 pCi/L. Because the property has an interior drain tile system connecting both units, the mitigation approach required careful planning, including discussions with the neighboring homeowner. Due to the electrical panel's location in the utility room, only one extraction point can be installed. The tight space around the home's exterior also presents challenges for routing the system and placing the fan. Given these limitations, a specific post-mitigation radon level cannot be guaranteed.
Radon Mitigation - George, IA
Radon Mitigation for Two Story Home With Future Addition Plans
This older two-story home tested at 6.8 pCi/L, prompting a smart radon mitigation plan designed with future expansion in mind. With another addition planned, the system will exit on the east side, avoiding interference with upcoming construction. The design includes two sub-slab extraction points on either side of the poured foundation wall, with one placed near the plumbing stack. The system will core low through the foundation and route around the soffit for a clean finish. Care was taken to preserve the homeowner’s layout, allowing furniture to remain in place. To further improve indoor air quality, the project also includes duct cleaning and a Breathe EZ filter installation.
Radon Mitigaiton - Sheldon, IA
Iowa Homeowner Reduces 7.6 Radon Levels with Professional Radon Mitigation
After a radon test revealed levels of 7.6 pCi/L, well above the EPA action level, an Iowa homeowner decided it was time to take proactive steps to protect the home for the future. While there were no immediate concerns, the homeowner understood the importance of reducing long-term radon exposure and improving indoor air quality. A home radon mitigation system was installed by Iowa Radon Defense Northwest to safely lower radon concentrations and prevent radon exposure poisoning Taking action today can help reduce health risks and provide lasting peace of mind for homeowners and their families.
Radon Mitigation - Paullina, IA
Extreme Radon Levels of 26–40 pCi/L Lead Homeowner to Begin Mitigation
A charcoal test revealed radon levels of 26 pCi/L, while the home's monitor displayed a reading of 40 pCi/L during the visit. These readings are significantly above the EPA's recommended action level of 4 pCi/L, making radon mitigation an important priority. An ERV system was discussed as another potential approach, but the homeowner chose to begin with a sub-slab depressurization system. The initial installation will address the selected areas rather than every chamber of the home. Because of the unusually high readings and the decision not to address all chambers initially, there is no guarantee that the system will bring radon levels below the recommended action level. Follow-up testing will be important to determine whether additional mitigation is needed.